Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 95 of 95 items found.

  • Surge Voltage Generator

    SSG 500 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit

  • RCD Testers

    PeakTech Prüf- und Messtechnik GmbH

    The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help